Industrial & commercial roofing and cladding

Industrial roofing and cladding for warehouses, factories, workshops and retail units: Delta 5 roofs to 150 mm, Star and Wall Design hidden-fix walls, mineral wool where the fire strategy needs A2-s1,d0 or EI ratings, and Dryclamp where the roof will carry solar.

Roof

Delta 5 at 80–120 mm is the standard industrial roof panel: 0.27–0.18 W/m²K, B-s1,d0 with a PIR core from 100 mm, REI30, BRoof(t3). For flat roofs under a membrane, Kappa 5 Deck or Sigma.

Walls and facade

Star (vertical) or Wall Design (horizontal) give a clean hidden-fix elevation; Onda adds a wave profile for the front of house; Airfix carries a rainscreen without drilling the panel.

Fire and solar

Where the fire consultant asks for non-combustible, Fibermet walls (EI120–EI180) and Lithos 5 roofs (REI120). Where the roof will carry PV, Dryclamp clamps the modules to the rib with no penetrations.

Products for this job

Delta 5

Insulated roof panel · 5 trapezoidal ribs · 30–150 mm · PUR / PIR

B-s1,d0REI30Solar-ready
View Delta 5

Dryclamp

Ventilated roof panel system · trapezoidal rib with patented clamp fixing (no through-drilling) · 30–140 mm · PUR / PIR

B-s1,d0REI30Solar-ready
View Dryclamp

Star

Insulated wall panel, hidden fixing · concealed (secret) fix joint · 40–160 mm · PUR / PIR

B-s1,d0
View Star

Wall Design

Architectural wall panel, hidden fixing · concealed fix, designed for horizontal installation (bottom-up) · 40–160 mm · PUR / PIR

B-s1,d0
View Wall Design

Onda

Wave-profile wall panel, hidden fixing · angled / wave face, concealed fix · 70–100 mm · PUR / PIR

B-s2,d0
View Onda

Fibermet

Mineral wool fire-rated wall panel · visible fix, seamless joint · 50–200 mm · Mineral wool

A2-s1,d0EI180
View Fibermet

Lithos 5

Mineral wool fire-rated roof panel · 5 trapezoidal ribs, 40 mm high, 250 mm module · 50–200 mm · Mineral wool

A2-s1,d0REI120Solar-ready
View Lithos 5

Compare the range

Declared values from manufacturer datasheets to EN 14509 and EN 13501. A dash means no rating is published.

ProductTypeCoreThicknessU @ 100 mmReaction to fireFire resistanceExternal fire
Delta 5 Insulated roof panel PUR / PIR 30–150 mm 0.22 B-s1,d0 REI30 BRoof(t3)
Dryclamp Ventilated roof panel system PUR / PIR 30–140 mm 0.22 B-s1,d0 REI30 BRoof(t3)
Star Insulated wall panel, hidden fixing PUR / PIR 40–160 mm 0.22 B-s1,d0
Wall Design Architectural wall panel, hidden fixing PUR / PIR 40–160 mm 0.22 B-s1,d0
Onda Wave-profile wall panel, hidden fixing PUR / PIR 70–100 mm 0.27 B-s2,d0
Fibermet Mineral wool fire-rated wall panel Mineral wool 50–200 mm 0.38 A2-s1,d0 EI180
Lithos 5 Mineral wool fire-rated roof panel Mineral wool 50–200 mm 0.39 A2-s1,d0 REI120 BRoof(cwft)
Kappa 5 Deck Insulated flat roof deck panel PUR / PIR 30–120 mm 0.22

Certifications on this range

Reaction to fire (EN 13501-1), fire resistance (EN 13501-2), external fire (EN 13501-5), EPD type III and CE marking. Classes depend on core and thickness and are confirmed at order.

Full certification tables

Industrial & commercial roofing and cladding questions

What fire class do industrial panels need in Ireland?

[DRAFT: confirm with client] It depends on the building's fire strategy and TGD Part B; insurers often ask for B-s1,d0 or better on PIR, or A2-s1,d0 mineral wool for compartment walls. We can supply either and provide the certificates.

Price industrial & commercial roofing and cladding

Tell us the job. We reply within one working day.

Or call +353 87 348 8884, Mon–Fri [HOURS]. We only use your details to answer this enquiry.

Call +353 87 348 8884 Get a quote